Inter-storey isolation (ISI) places seismic isolation bearings at an intermediate storey so that the upper storey block is isolated while the lower storey block behaves as a massive tuned mass damper. Saha and Mishra (2021) showed that near-fault pulse-type ground motions amplify ISI design demands — with 84th-percentile amplification factors up to about 3.3 for upper-block displacement and roughly three-fold increases in bearing hysteretic energy — and that the FEMA-450-type closed-form displacement estimate requires an empirical correction factor that they could tabulate only per configuration. The surviving open problem is: design-usable predictive relationships for pulse-induced amplification — above all the regression of (and of amplification factors) as continuous functions of bearing period, effective damping, and upper/lower-substructure relative flexibility, statistically validated over an expanded frame/bearing/record database — together with a systematic account of how pulse arrival timing (early versus late) governs mobilization of the isolation/tuned-mass-damper mechanism and the resulting amplification. A 2025 follow-up by the first author delivered empirical prediction equations for inter-storey drift and floor-acceleration demands, partially resolving one item of the source's future-work list, but the displacement-correction regression and the pulse-timing question remain unaddressed in the literature to date.
Background
Seismic isolation decouples a building from the horizontal components of ground shaking by interposing flexible, energy-dissipating bearings between the structure and the ground. In inter-storey isolation (ISI), a strategy proposed for taller buildings, the isolation layer is moved from the base to an intermediate storey: the bearings separate an upper storey block (USB) from a lower storey block (LSB), so that the USB is isolated from earthquake input while the LSB, driven through the bearings, behaves like a tuned mass damper (TMD) — a vibration-control device in which a mass attached through springs and dampers counteracts structural motion — here a 'non-conventional TMD' whose mass ratio (USB mass to LSB mass) can approach 100%, far above the few-percent ratios of classical TMDs. The bearings most studied for ISI are high-damping rubber bearings (HDRBs), laminated rubber-steel composites whose horizontal force-deformation response exhibits pre-yield stiffness, post-yield hardening, and a secondary stiffening branch at large shear strains.
Near-fault ground motions produced by forward directivity — rupture propagating toward the site — contain a coherent long-period velocity pulse, typically with a period of one to several seconds, whose energy can coincide with both the isolation period and the natural periods of tall buildings; pulse-like records are conventionally identified, and their pulse period extracted, with Baker's wavelet-based classification algorithm (Baker, 2007). For conventional base isolation it has long been known that such pulses degrade isolation performance; whether the mass partitioning and lower-block flexibility of ISI filter out or instead transmit and amplify the pulse energy was, before the source study, unquantified.
Saha and Mishra (2021) addressed this with 2,744 nonlinear time-history analyses of six steel special moment-resisting frame configurations (designated B1–B4, with storey-partition variants), four HDRB parameterizations (HDRB-A to HDRB-D), and suites of 25 near-fault pulse records drawn from Baker's database against a comparable near-fault non-pulse suite, amplitude-scaled to design-basis and maximum-considered-earthquake levels. They reported 84th-percentile amplification factors — the ratio of the 84th-percentile response under the pulse suite to that under the non-pulse suite — of roughly 1.7 to 3.3 for peak floor displacement at the top of the USB, and about three-fold increases in bearing hysteretic energy dissipation. They further showed that the closed-form isolation-bearing displacement estimate used in the NEHRP provisions (FEMA-450), — with the gravitational acceleration, the 5%-damped spectral acceleration ordinate at 1 s, the bearing vibration period, and the damping-reduction coefficient for the bearing's effective viscous damping — systematically underestimates the simulated pulse-driven bearing displacement in ISI configurations, and introduced an empirical correction factor (the ratio of simulated peak ISI bearing displacement to the closed-form estimate), tabulated per frame/bearing combination at its median and 84th percentile. Raising the USB/LSB mass ratio toward 100% and the bearing effective damping toward about 20% were identified as the principal mitigation levers.
The same authors' companion studies extended intensity-measure-based demand prediction for ISI under near-fault motions (a vector-valued intensity measure, 2021) and consequence modeling (fragility, expected annual loss, and resilience, 2022). A 2025 follow-up by the first author proposed empirical prediction equations for the inter-storey drift ratio and peak floor acceleration of ISI frames under near-fault pulse motions, built on recorded motions and a calibrated equivalent mathematical pulse model, with pulse amplitude, pulse period, oscillatory characteristics, phase angle, moment magnitude, and source distance as predictor concepts and a coefficient of determination above 0.80. No published work yet provides the design-usable regression of the displacement-correction factor — or of pulse amplification generally — on the isolation design parameters themselves, and no systematic treatment of pulse arrival timing for ISI systems exists; timing effects have so far been studied only for fixed-base single-degree-of-freedom systems and reinforced-concrete frames.
Problem Statement
Establish design-usable predictive relationships for near-fault pulse-induced amplification of seismic demands in inter-storey-isolated (ISI) buildings, as left open by Saha and Mishra (2021) and not resolved by subsequent literature. As used here, 'design-usable' means a relationship expressed directly in the isolation design parameters, accompanied by an explicitly reported validated range and a quantitative accuracy or dispersion measure, and adequate to replace configuration-specific tabulated values in the corresponding design check. The problem has two jointly necessary components serving one objective — a validated, design-usable predictive account of pulse amplification for ISI buildings — each of which must be statistically validated over an explicitly defined parameter and record space:
(1) Predictive regression relationships, continuous in the principal isolation design parameters — bearing (isolation) period , effective damping , and a measure of relative flexibility between the upper storey block (USB) and the lower storey block (LSB), such as the ratio of their effective periods or stiffnesses — for the amplification of design demands under pulse-type near-fault motions relative to non-pulse near-fault motions. The mandatory members of component (1) are the empirical correction factor that converts the FEMA-450-type closed-form displacement estimate into the pulse-amplified bearing displacement demand of ISI configurations, together with the corresponding amplification-factor regressions for the other design demands quantified by the source study — the peak floor displacement at the top of the USB and the bearing hysteretic energy. The relationships must be statistically validated over a database of building frames, bearing designs, and pulse/non-pulse record suites that exceeds the source study's scope in frame/bearing breadth and record count — the source study's six frame configurations, four HDRB parameterizations, and roughly 25-record suites being explicitly acknowledged by its authors as insufficient for generalization — and the validated parameter ranges and a quantitative goodness-of-fit or dispersion measure must be reported.
(2) A systematic account of pulse arrival timing — early- versus late-arriving pulses — covering how timing governs mobilization of the isolation/non-conventional-tuned-mass-damper mechanism and the resulting amplification of the design demands, carried far enough to yield design-useful criteria rather than illustrative examples.
The source's further extensions — multi-directional excitation, alternative bearing technologies, and combined pulse-plus-fling-step hazards — are recorded as desirable future work beyond the scope of this problem; likewise, the drift- and floor-acceleration demand prediction equations already published for ISI under near-fault pulses (Saha, 2025) do not by themselves resolve component (1), which requires regression relationships continuous in the isolation design parameters.
References
- Arijit Saha and Sudib Kumar Mishra (2021). Amplification of seismic demands in inter-storey-isolated buildings subjected to near fault pulse type ground motions. Soil Dynamics and Earthquake Engineering 147:106771. DOI: 10.1016/j.soildyn.2021.106771. https://doi.org/10.1016/j.soildyn.2021.106771 (source paper)
- Arijit Saha (2025). Seismic Demand Prediction Models for the Inter-Story Isolated Building Frame Subjected to Near-Fault Pulse-Type Ground Motions. The Structural Design of Tall and Special Buildings 34(17):e70103. DOI: 10.1002/tal.70103. https://doi.org/10.1002/tal.70103
- Arijit Saha and Sudib Kumar Mishra (2021). Synthesis of a vector-valued intensity measure for improved prediction of seismic demands in Inter-Story-Isolated (ISI) buildings subjected to near fault ground motions. Engineering Structures 248:113241. DOI: 10.1016/j.engstruct.2021.113241. https://doi.org/10.1016/j.engstruct.2021.113241
- Arijit Saha and Sudib Kumar Mishra (2022). Implications of inter-storey-isolation (ISI) on seismic fragility, loss and resilience of buildings subjected to near fault ground motions. Bulletin of Earthquake Engineering 20(2):899–939. DOI: 10.1007/s10518-021-01277-9. https://doi.org/10.1007/s10518-021-01277-9
- Cuihua Li, Sashi Kunnath, and Changhai Zhai (2020). Influence of Early-Arriving Pulse-Like Ground Motions on Ductility Demands of Single-Degree-of-Freedom Systems. Journal of Earthquake Engineering 24(9):1337–1360. DOI: 10.1080/13632469.2018.1466744. https://doi.org/10.1080/13632469.2018.1466744
- Cuihua Li, Sashi Kunnath, Zhanxuan Zuo, Weibing Peng, and Changhai Zhai (2020). Effects of early-arriving pulse-like ground motions on seismic demands in RC frame structures. Soil Dynamics and Earthquake Engineering 130:105997. DOI: 10.1016/j.soildyn.2019.105997. https://doi.org/10.1016/j.soildyn.2019.105997
- Kui Yang, Ping Tan, Huating Chen, Jiaxi Li, and Jiajun Tan (2024). Prediction of nonlinear seismic demand of inter-story isolated systems using improved multi-modal pushover analysis procedures. Journal of Building Engineering 82:108322. DOI: 10.1016/j.jobe.2023.108322. https://doi.org/10.1016/j.jobe.2023.108322
- Yang Liu, Dewen Liu, and Haozhe Hu (2025). Optimal design and performance of inter-story isolation system with inerter damper considering soil–structure interaction under near-fault pulse-like ground motions. Canadian Journal of Civil Engineering 52(7):1470–1486. DOI: 10.1139/cjce-2024-0478. https://doi.org/10.1139/cjce-2024-0478
- Zhibin Xian, Ping Tan, Wenzhi Zheng, Kui Yang, Yue Xiang, and Yuze Zheng (2026). Seismic performance of inter-story isolated structure with shape memory alloy variable curvature friction pendulum bearings. Soil Dynamics and Earthquake Engineering 200:109737. DOI: 10.1016/j.soildyn.2025.109737. https://doi.org/10.1016/j.soildyn.2025.109737
- Sukamal Kanta Ghosh, Indrajeet Kashyap, and Diptesh Das (2026). Machine learning-enhanced metaheuristic optimization of lead rubber bearings for inter-story isolated buildings under seismic load. Frontiers of Structural and Civil Engineering 20(1):36–79. DOI: 10.1007/s11709-026-1275-y. https://doi.org/10.1007/s11709-026-1275-y
- Xinyu Wang, Linlin Xie, Aiqun Li, and Cantian Yang (2026). Seismic performance of inter-story isolated towers built on large chassis under far-field and near-field pulse-like ground motions: shaking table test and numerical investigation. Journal of Building Engineering 128:116747. DOI: 10.1016/j.jobe.2026.116747. https://doi.org/10.1016/j.jobe.2026.116747
- Ming Wen, Xiaohan Lai, Wangde Qiu, Yanqing Xu, Baokui Chen, and Zhiqiang Liu (2026). Seismic performance of a partial seismic isolation system for high-rise hospital buildings under near-fault pulse ground motions. Soil Dynamics and Earthquake Engineering 208:110409. DOI: 10.1016/j.soildyn.2026.110409. https://doi.org/10.1016/j.soildyn.2026.110409
- J. W. Baker (2007). Quantitative Classification of Near-Fault Ground Motions Using Wavelet Analysis. Bulletin of the Seismological Society of America 97(5):1486–1501. DOI: 10.1785/0120060255. https://doi.org/10.1785/0120060255