Inter-storey isolation (ISI) places seismic isolation bearings at an intermediate storey so that the upper storey block is isolated while the lower storey block behaves as a massive tuned mass damper. Saha and Mishra (2021) showed that near-fault pulse-type ground motions amplify ISI design demands — with 84th-percentile amplification factors up to about 3.3 for upper-block displacement and roughly three-fold increases in bearing hysteretic energy — and that the FEMA-450-type closed-form displacement estimate requires an empirical correction factor CrC_r that they could tabulate only per configuration. The surviving open problem is: design-usable predictive relationships for pulse-induced amplification — above all the regression of CrC_r (and of amplification factors) as continuous functions of bearing period, effective damping, and upper/lower-substructure relative flexibility, statistically validated over an expanded frame/bearing/record database — together with a systematic account of how pulse arrival timing (early versus late) governs mobilization of the isolation/tuned-mass-damper mechanism and the resulting amplification. A 2025 follow-up by the first author delivered empirical prediction equations for inter-storey drift and floor-acceleration demands, partially resolving one item of the source's future-work list, but the displacement-correction regression and the pulse-timing question remain unaddressed in the literature to date.

Background

Seismic isolation decouples a building from the horizontal components of ground shaking by interposing flexible, energy-dissipating bearings between the structure and the ground. In inter-storey isolation (ISI), a strategy proposed for taller buildings, the isolation layer is moved from the base to an intermediate storey: the bearings separate an upper storey block (USB) from a lower storey block (LSB), so that the USB is isolated from earthquake input while the LSB, driven through the bearings, behaves like a tuned mass damper (TMD) — a vibration-control device in which a mass attached through springs and dampers counteracts structural motion — here a 'non-conventional TMD' whose mass ratio (USB mass to LSB mass) can approach 100%, far above the few-percent ratios of classical TMDs. The bearings most studied for ISI are high-damping rubber bearings (HDRBs), laminated rubber-steel composites whose horizontal force-deformation response exhibits pre-yield stiffness, post-yield hardening, and a secondary stiffening branch at large shear strains.

Near-fault ground motions produced by forward directivity — rupture propagating toward the site — contain a coherent long-period velocity pulse, typically with a period of one to several seconds, whose energy can coincide with both the isolation period and the natural periods of tall buildings; pulse-like records are conventionally identified, and their pulse period TpT_p extracted, with Baker's wavelet-based classification algorithm (Baker, 2007). For conventional base isolation it has long been known that such pulses degrade isolation performance; whether the mass partitioning and lower-block flexibility of ISI filter out or instead transmit and amplify the pulse energy was, before the source study, unquantified.

Saha and Mishra (2021) addressed this with 2,744 nonlinear time-history analyses of six steel special moment-resisting frame configurations (designated B1–B4, with storey-partition variants), four HDRB parameterizations (HDRB-A to HDRB-D), and suites of 25 near-fault pulse records drawn from Baker's database against a comparable near-fault non-pulse suite, amplitude-scaled to design-basis and maximum-considered-earthquake levels. They reported 84th-percentile amplification factors — the ratio of the 84th-percentile response under the pulse suite to that under the non-pulse suite — of roughly 1.7 to 3.3 for peak floor displacement at the top of the USB, and about three-fold increases in bearing hysteretic energy dissipation. They further showed that the closed-form isolation-bearing displacement estimate used in the NEHRP provisions (FEMA-450), Dd=(g/4π2)(SdT/B)D_d=(g/4\pi^2)(S_d T/B) — with gg the gravitational acceleration, SdS_d the 5%-damped spectral acceleration ordinate at 1 s, TT the bearing vibration period, and BB the damping-reduction coefficient for the bearing's effective viscous damping — systematically underestimates the simulated pulse-driven bearing displacement in ISI configurations, and introduced an empirical correction factor Cr=DISI/DdC_r=D_{ISI}/D_d (the ratio of simulated peak ISI bearing displacement to the closed-form estimate), tabulated per frame/bearing combination at its median and 84th percentile. Raising the USB/LSB mass ratio toward 100% and the bearing effective damping toward about 20% were identified as the principal mitigation levers.

The same authors' companion studies extended intensity-measure-based demand prediction for ISI under near-fault motions (a vector-valued intensity measure, 2021) and consequence modeling (fragility, expected annual loss, and resilience, 2022). A 2025 follow-up by the first author proposed empirical prediction equations for the inter-storey drift ratio and peak floor acceleration of ISI frames under near-fault pulse motions, built on recorded motions and a calibrated equivalent mathematical pulse model, with pulse amplitude, pulse period, oscillatory characteristics, phase angle, moment magnitude, and source distance as predictor concepts and a coefficient of determination above 0.80. No published work yet provides the design-usable regression of the displacement-correction factor — or of pulse amplification generally — on the isolation design parameters themselves, and no systematic treatment of pulse arrival timing for ISI systems exists; timing effects have so far been studied only for fixed-base single-degree-of-freedom systems and reinforced-concrete frames.

Problem Statement

Establish design-usable predictive relationships for near-fault pulse-induced amplification of seismic demands in inter-storey-isolated (ISI) buildings, as left open by Saha and Mishra (2021) and not resolved by subsequent literature. As used here, 'design-usable' means a relationship expressed directly in the isolation design parameters, accompanied by an explicitly reported validated range and a quantitative accuracy or dispersion measure, and adequate to replace configuration-specific tabulated values in the corresponding design check. The problem has two jointly necessary components serving one objective — a validated, design-usable predictive account of pulse amplification for ISI buildings — each of which must be statistically validated over an explicitly defined parameter and record space:

(1) Predictive regression relationships, continuous in the principal isolation design parameters — bearing (isolation) period TT, effective damping β\beta, and a measure of relative flexibility between the upper storey block (USB) and the lower storey block (LSB), such as the ratio of their effective periods or stiffnesses — for the amplification of design demands under pulse-type near-fault motions relative to non-pulse near-fault motions. The mandatory members of component (1) are the empirical correction factor Cr=DISI/DdC_r=D_{ISI}/D_d that converts the FEMA-450-type closed-form displacement estimate DdD_d into the pulse-amplified bearing displacement demand of ISI configurations, together with the corresponding amplification-factor regressions for the other design demands quantified by the source study — the peak floor displacement at the top of the USB and the bearing hysteretic energy. The relationships must be statistically validated over a database of building frames, bearing designs, and pulse/non-pulse record suites that exceeds the source study's scope in frame/bearing breadth and record count — the source study's six frame configurations, four HDRB parameterizations, and roughly 25-record suites being explicitly acknowledged by its authors as insufficient for generalization — and the validated parameter ranges and a quantitative goodness-of-fit or dispersion measure must be reported.

(2) A systematic account of pulse arrival timing — early- versus late-arriving pulses — covering how timing governs mobilization of the isolation/non-conventional-tuned-mass-damper mechanism and the resulting amplification of the design demands, carried far enough to yield design-useful criteria rather than illustrative examples.

The source's further extensions — multi-directional excitation, alternative bearing technologies, and combined pulse-plus-fling-step hazards — are recorded as desirable future work beyond the scope of this problem; likewise, the drift- and floor-acceleration demand prediction equations already published for ISI under near-fault pulses (Saha, 2025) do not by themselves resolve component (1), which requires regression relationships continuous in the isolation design parameters.

References

  1. Arijit Saha and Sudib Kumar Mishra (2021). Amplification of seismic demands in inter-storey-isolated buildings subjected to near fault pulse type ground motions. Soil Dynamics and Earthquake Engineering 147:106771. DOI: 10.1016/j.soildyn.2021.106771. https://doi.org/10.1016/j.soildyn.2021.106771 (source paper)
  2. Arijit Saha (2025). Seismic Demand Prediction Models for the Inter-Story Isolated Building Frame Subjected to Near-Fault Pulse-Type Ground Motions. The Structural Design of Tall and Special Buildings 34(17):e70103. DOI: 10.1002/tal.70103. https://doi.org/10.1002/tal.70103
  3. Arijit Saha and Sudib Kumar Mishra (2021). Synthesis of a vector-valued intensity measure for improved prediction of seismic demands in Inter-Story-Isolated (ISI) buildings subjected to near fault ground motions. Engineering Structures 248:113241. DOI: 10.1016/j.engstruct.2021.113241. https://doi.org/10.1016/j.engstruct.2021.113241
  4. Arijit Saha and Sudib Kumar Mishra (2022). Implications of inter-storey-isolation (ISI) on seismic fragility, loss and resilience of buildings subjected to near fault ground motions. Bulletin of Earthquake Engineering 20(2):899–939. DOI: 10.1007/s10518-021-01277-9. https://doi.org/10.1007/s10518-021-01277-9
  5. Cuihua Li, Sashi Kunnath, and Changhai Zhai (2020). Influence of Early-Arriving Pulse-Like Ground Motions on Ductility Demands of Single-Degree-of-Freedom Systems. Journal of Earthquake Engineering 24(9):1337–1360. DOI: 10.1080/13632469.2018.1466744. https://doi.org/10.1080/13632469.2018.1466744
  6. Cuihua Li, Sashi Kunnath, Zhanxuan Zuo, Weibing Peng, and Changhai Zhai (2020). Effects of early-arriving pulse-like ground motions on seismic demands in RC frame structures. Soil Dynamics and Earthquake Engineering 130:105997. DOI: 10.1016/j.soildyn.2019.105997. https://doi.org/10.1016/j.soildyn.2019.105997
  7. Kui Yang, Ping Tan, Huating Chen, Jiaxi Li, and Jiajun Tan (2024). Prediction of nonlinear seismic demand of inter-story isolated systems using improved multi-modal pushover analysis procedures. Journal of Building Engineering 82:108322. DOI: 10.1016/j.jobe.2023.108322. https://doi.org/10.1016/j.jobe.2023.108322
  8. Yang Liu, Dewen Liu, and Haozhe Hu (2025). Optimal design and performance of inter-story isolation system with inerter damper considering soil–structure interaction under near-fault pulse-like ground motions. Canadian Journal of Civil Engineering 52(7):1470–1486. DOI: 10.1139/cjce-2024-0478. https://doi.org/10.1139/cjce-2024-0478
  9. Zhibin Xian, Ping Tan, Wenzhi Zheng, Kui Yang, Yue Xiang, and Yuze Zheng (2026). Seismic performance of inter-story isolated structure with shape memory alloy variable curvature friction pendulum bearings. Soil Dynamics and Earthquake Engineering 200:109737. DOI: 10.1016/j.soildyn.2025.109737. https://doi.org/10.1016/j.soildyn.2025.109737
  10. Sukamal Kanta Ghosh, Indrajeet Kashyap, and Diptesh Das (2026). Machine learning-enhanced metaheuristic optimization of lead rubber bearings for inter-story isolated buildings under seismic load. Frontiers of Structural and Civil Engineering 20(1):36–79. DOI: 10.1007/s11709-026-1275-y. https://doi.org/10.1007/s11709-026-1275-y
  11. Xinyu Wang, Linlin Xie, Aiqun Li, and Cantian Yang (2026). Seismic performance of inter-story isolated towers built on large chassis under far-field and near-field pulse-like ground motions: shaking table test and numerical investigation. Journal of Building Engineering 128:116747. DOI: 10.1016/j.jobe.2026.116747. https://doi.org/10.1016/j.jobe.2026.116747
  12. Ming Wen, Xiaohan Lai, Wangde Qiu, Yanqing Xu, Baokui Chen, and Zhiqiang Liu (2026). Seismic performance of a partial seismic isolation system for high-rise hospital buildings under near-fault pulse ground motions. Soil Dynamics and Earthquake Engineering 208:110409. DOI: 10.1016/j.soildyn.2026.110409. https://doi.org/10.1016/j.soildyn.2026.110409
  13. J. W. Baker (2007). Quantitative Classification of Near-Fault Ground Motions Using Wavelet Analysis. Bulletin of the Seismological Society of America 97(5):1486–1501. DOI: 10.1785/0120060255. https://doi.org/10.1785/0120060255