A 2011 protocol demonstrated that a contact acoustic nonlinearity (CAN) microscope, combined with a model-based inversion and a chain of calibrations, can map the absolute local vertical bonding strength B0(x,y)B_0(x,y) at a bonded solid–solid interface. Its quantitative character, however, rests on a destructive tensile pull-off reference strength BB calibrated for each adhesive–substrate system, an unquantified calibration chain (the incident focal amplitude AA and the receiver transfer function H(ω)H(\omega)), and a demonstration confined to glass specimens, one 5 MHz focusing geometry, and two adhesives. The open problem is to convert this demonstrated-but-qualified protocol into a validated measurement capability: recover spatially resolved absolute bonding strength nondestructively, establishing the absolute strength reference without destructive tensile pull-off calibration, with the absolute accuracy of the recovered strengths demonstrable against independent strength measurements.

Background

Adhesive and diffusion-bonded layered structures are used in safety-critical aerospace, automotive, and composite components, and their load-bearing capacity is set by the mechanical quality of the bonded solid–solid interfaces. Ultrasonic nondestructive evaluation (NDE) readily images gross defects such as voids and disbonds, but the review literature going back to Guyott, Cawley and Adams (1986) has consistently distinguished defect detection from the measurement of bond strength, and the latter has remained outside established NDE capability. Two specialist notions are needed. Contact acoustic nonlinearity (CAN) denotes the strong nonlinearity that arises when an acoustic wave crosses an imperfectly bonded interface: interfacial micro-gaps open and close ("clap") under the wave's oscillatory pressure, so an incident tone of frequency ff is partly converted into a second harmonic at 2f2f; the relative size of this conversion, commonly summarized by the CAN parameter A2/A12A_2/A_1^2 (second-harmonic amplitude divided by the squared fundamental amplitude), grows with the degree of interfacial imperfection. A kissing bond is an interface that is fully closed and hence nearly invisible to conventional (linear) ultrasound yet transmits little structural load; nonlinear methods are pursued precisely for such weak bonds.

Building on earlier studies of CAN at bonded interfaces, Chen, Zhang, Mao and Cheng developed a CAN microscope protocol culminating in the 2011 paper at issue here. A focusing transducer (a 5 MHz source on a glass lens, coupled through water) scans the interface and a 10 MHz piezoelectric receiver detects the transmitted wave. The interface is modeled by an unbonded area fraction RR within the acoustic focal spot, and the local vertical (normal-to-interface) bonding strength is defined as B0=B(1−R)B_0 = B(1-R), where BB is the vertical bonding strength of a fully bonded interface of the same adhesive–substrate system. A piecewise waveform model (separating open-crack and closed-crack intervals of the acoustic cycle) links the transmitted waveform, and hence the measurable CAN parameter A2/A12A_2/A_1^2, to B0B_0. To evaluate the inversion, the paper calibrates three ingredients: (i) the incident vibration amplitude AA at the buried interface, obtained from a laser-vibrometer measurement (a laser interferometer measuring surface vibration) of the lens-surface amplitude together with a theoretically computed focusing amplification, giving A=1.5×10−7 mA = 1.5\times10^{-7}\,\mathrm{m}; (ii) the receiving transducer's transfer function H(ω)H(\omega) — the frequency-dependent factor converting the recorded electrical spectral components at 5 and 10 MHz into physical vibration amplitudes — calibrated on a separate transducer of the same model; and (iii) the absolute reference BB, obtained for each of the two adhesives used (neoprene+Bakelite glue, B=99.4B = 99.4 kg/cm²; epoxy, B=201B = 201 kg/cm²) from destructive tensile pull-off tests on separately prepared fully bonded samples. The output is a contour map of B0(x,y)B_0(x,y) over two bonded glass samples, validated only qualitatively, by agreement of the spatial pattern with optical photographs of the interface.

This was the first end-to-end demonstration that a locally measured nonlinear acoustic response can be converted into an absolute local strength map. But, as the protocol itself makes clear, three prerequisites keep it from being a fully nondestructive and generally applicable measurement: the destructive reference BB (so the method is nondestructive only after a destructive materials calibration), the absence of any uncertainty or sensitivity analysis for the calibration chain (AA, H(ω)H(\omega), and the interface-model parameters), and the restriction of the demonstration to one material system, one frequency, one focusing geometry, and two adhesives. Later work has improved convenience and begun uncertainty-quantification research along a different observable, but has not removed these prerequisites.

Problem Statement

Develop and validate a measurement protocol that recovers the spatially resolved, absolute vertical bonding strength B0(x,y)B_0(x,y) at a bonded solid–solid interface from nondestructive acoustic measurements, within the interface model B0=B(1−R)B_0 = B(1-R), such that the absolute strength reference — the full-bond strength BB of the adhesive–substrate system — is established without destructive tensile pull-off calibration, and the absolute accuracy of the recovered strength map is demonstrable against independent strength measurements (destructive tests are permissible for such external verification, though not for calibration). The protocol must additionally quantify the uncertainty of the calibration chain — the incident focal amplitude AA, the receiver transfer function H(ω)H(\omega), and the interface-model parameters — and report the uncertainty of the resulting B0(x,y)B_0(x,y) map, so that the recovered strength is uncertainty-quantified. The independent verification must be capable of certifying the spatial variation of the recovered map, not only its overall scale, by comparison against an independent measurement that supplies spatial ground truth at a resolution sufficient to resolve that variation.

References

  1. Jian-Jun Chen, De Zhang, Yi-Wei Mao, Jian-Chun Cheng (2011). 'Nondestructive Characterization of Quantitative Bonding Strength at a Bonded Solid-Solid Interface.' Chinese Physics Letters 28, 084301. DOI: 10.1088/0256-307X/28/8/084301. https://doi.org/10.1088/0256-307X/28/8/084301
  2. Jianjun Chen, De Zhang, Yiwei Mao, Jianchun Cheng (2006). 'Contact acoustic nonlinearity in a bonded solid–solid interface.' Ultrasonics 44, e1355–e1358. DOI: 10.1016/j.ultras.2006.05.051. https://doi.org/10.1016/j.ultras.2006.05.051
  3. Jian-Jun Chen, De Zhang, Yi-Wei Mao, Jian-Chun Cheng (2009). 'A Unique Method to Describe the Bonding Strength in a Bonded Solid–Solid Interface by Contact Acoustic Nonlinearity.' Chinese Physics Letters 26, 014302. DOI: 10.1088/0256-307X/26/1/014302. https://doi.org/10.1088/0256-307X/26/1/014302
  4. Jian-jun Chen, De Zhang, Yi-wei Mao (2012). 'A CAN method to image the quantitative bonding strength at the bonded solid-solid interface.' 2012 Symposium on Piezoelectricity, Acoustic Waves, and Device Applications (SPAWDA), pp. 266–269. DOI: 10.1109/SPAWDA.2012.6464085. https://doi.org/10.1109/SPAWDA.2012.6464085
  5. Jianjun Chen (2012). 'A quantitative imaging of bonding strength at the bonded solid-solid interface obtained by nonlinear test.' The Journal of the Acoustical Society of America 131 (4_Supplement), 3462. DOI: 10.1121/1.4709049. https://doi.org/10.1121/1.4709049
  6. Jian-Jun Chen, De Zhang, Xiao-Zhou Liu (2014). 'A Reflective Nonlinear Acoustic Microscope to Contour the Quantitative Adhesion at a Bonded Solid–Solid Interface.' Chinese Physics Letters 31, 094301. DOI: 10.1088/0256-307X/31/9/094301. https://doi.org/10.1088/0256-307X/31/9/094301
  7. C. C. H. Guyott, P. Cawley, R. D. Adams (1986). 'The Non-destructive Testing of Adhesively Bonded Structure: A Review.' The Journal of Adhesion 20, 129–159. DOI: 10.1080/00218468608074943. https://doi.org/10.1080/00218468608074943
  8. John H. Cantrell (2018). 'Assessment of Adhesive Bond Strength from Ultrasonic Tone-Bursts.' Journal of Nondestructive Evaluation 37, 81. DOI: 10.1007/s10921-018-0530-0. https://doi.org/10.1007/s10921-018-0530-0
  9. Paul Zabbal, Guillemette Ribay, Julien Jumel (2019). 'Nonlinear ultrasound for nondestructive evaluation of adhesive joints.' AIP Conference Proceedings 2102, 020030. DOI: 10.1063/1.5099734. https://doi.org/10.1063/1.5099734
  10. Jihyun Jun, Kyung-Young Jhang (2020). 'Indirect Method for Measuring Absolute Acoustic Nonlinearity Parameter Using Surface Acoustic Waves with a Fully Non-Contact Laser-Ultrasonic Technique.' Applied Sciences 10, 5911. DOI: 10.3390/app10175911. https://doi.org/10.3390/app10175911
  11. Do-Kyung Pyun, Lucas W. Koester, Daniel J. Barnard, Leonard J. Bond (2022). 'Nonlinear Ultrasonic Inspection of the Effect of Contaminants on Material Properties of Epoxy-Adhesive.' Journal of Nondestructive Evaluation 41, 75. DOI: 10.1007/s10921-022-00904-y. https://doi.org/10.1007/s10921-022-00904-y
  12. Igor Solodov, Mike Kornely, Jens Philipp, Elisabeth Stammen, Klaus Dilger, Marc Kreutzbruck (2023). 'Linear vs nonlinear ultrasonic testing of kissing bonds in adhesive joints.' Ultrasonics 132, 106967. DOI: 10.1016/j.ultras.2023.106967. https://doi.org/10.1016/j.ultras.2023.106967
  13. Sourav Banerjee, Vahid Tavaf, Mustahseen M. Indaleeb (2024). 'Ultrasonic Nondestructive Evaluation of Composite Bond Strength: Quantification through Bond Quality Index (BQI).' Journal of Composites Science 8, 107. DOI: 10.3390/jcs8030107. https://doi.org/10.3390/jcs8030107
  14. Michael C. Stanley, Peter W. Spaeth, James E. Warner, Matthew R. Webster (2025). 'Bond strength uncertainty quantification via confidence intervals for nondestructive evaluation of bonded composites.' arXiv:2512.13875. DOI: 10.48550/arXiv.2512.13875. https://arxiv.org/abs/2512.13875
  15. Jiung Yoo, Dong-Gi Song, Kyung-Young Jhang (2025). 'Compensation of system nonlinearity in the measurement of acoustic nonlinearity parameters.' Ultrasonics 145, 107484. DOI: 10.1016/j.ultras.2024.107484. https://doi.org/10.1016/j.ultras.2024.107484